LAB SCOPE
|
* Menu driven, designed for the mechanic * Troubleshooting by comparing waveforms * Programmable flash card for automatic set-up |
The hottest new diagnostic lab scope for the automotive world
The LS 2000 is a hand-held oscilloscope designed specifically for diagnostic troubleshooting. The operation is extremely simple and does not require that the user is an expert in oscilloscopes. As a result, the LS 2000 is the most useful lab scope a diagnostic automotive technician could use. The LS 2000 is a two channel portable digital oscilloscope with a 5″ LCD screen. All functions are controlled by soft buttons located around the perimeter of the screen. Reference waveforms and instructions are contained in a plug- in card that can set up the scope for each specific measurement. Operation in reference mode is simple: scroll through the stored waveforms until you reach the desired measurement: the scope will then set all functions and display the reference waveform and the signal of the tested vehicle.
In addition, the LS 2000 can be used as a general purpose lab scope for troubleshooting and repair. There are no hidden functions, you cannot get lost in a programm. It is very user friendly even testing while driving.
The LS 2000 comes standard complete with testleads, inductive pick-up clamp and 12V adaptor in a solid case.
Technical Specifications
Vertical deflection: |
Sampling rate Bandwidth Resolution Deflection Input impedance Accuracy Coupling Maximum input voltage |
4MS/s(Mega-Samples/s) DC: DC to 1 Mhz, AC: 10 Hz to 500 KHz 8 bits 50 mV/Div to 10 V/Div in 1,2,5 sequence 10 M/Ohm +/- 2%,25 pf +/-5% +/-5% DC (Default), AC 500 V (DC + AC p-p) |
Horizontal deflection: |
Resolution Sweep rate Triggering mode Pre-trigger Source Slope Memory capacity |
8 bits, 512 pixels 5 uS Div to 60 S/Div in 1,2,5 sequence Roll mode below 100 Ms/Div auto DC (50% point) with selectable AC fixed at two divisions (20%) internal only, CH1 + or – (default to +) 4 waveforms @ 256 points each |
Acquisition: | Minimum/Maximum always | |
Interface: | Format | RS232C, talk/listen with optional adaptor |
Display: | Total area | LCD 320 x 512 matrix |
Memory: | Format Operation Content |
Card format 128K x 8 OTP scroll through each bank contains up to 15 waveforms, character descriptions and oscilloscope settings. |
Power supply: | Internal lead acid pack external | 12 V DC |