MODULAR GAS ANALYSER
|
The modular gas analyser is a modern gas analyser ready for the future. The unit is designed to meet the performance requirements of OIML Class 1 and ISO 3930. The standard software supports measurements of 4 gases, rpm, oil temperature and Lambda and a clock-calendar feature. The measurements are displayed on six, very bright, twenty millimetre LED display elements. A print-out can be made with the built-in-printer. The RS 232 connection provides you with the possibility to interface with other equipment like sun’s testlanes.
Simple controls
The simple controls of the MGA 1500, thumbwheel, right/left arrow key, function-, print- and mode/cancel buttons, allow effortless navigation through the program.
Rpm Measurement
Measuring rpm, on all types of ignition systems, is no problem for the MGA 1500. Engine speed, rpm, can be measured by an inductive pick-up clamp on ignition secondary cables, by capacitive pick-up on a primary wire or an injector wire, or via a direct connection to a square wave from the engine management system. This way you are able to measure rpm on conventional, wastedspark and direct ignition systems.
Technical Specifications
SCALE RANGES Measured Quantity |
Range & Resolution |
Accuracy Relative (± ) % of reading |
Accuracy near zero reading |
CO CO CO cor. CO2 HC O2 rpm Oil temp |
0.000 to 9.999% vol 10.00 to 15.00 % vol 0.00 to 9.99 % vol 0.00 to 20.00 % vol 0.00 to 9.999 ppm 0.00 to 25.00 % vol 0 to 9.999 rpm -10 to + 150 ° C |
5 % 5 % |
0.06 % vol 0.5 % vol 12 ppm |
OPERATING CONDITIONS | OPTIONS | ||
Temperature Relative humidity Atmospheric pressure Mains voltage Mains frequency |
5…45 ° C up to 90 % 750…1100 mbar 90…260 V~ 47…63 Hz |
12 to 230 V adaptor for in-car use Portable test stand, cart assembly Capacitive trigger pick-up Primary ECU rpm adaptor High temperature exhaust probe kit |
|
GENERAL | *Options subject to change per country | ||
Weight Noise level |
10 kg 50 dB |